Energy Performance Certificate

47, Crown Lane, BR2 9PG

EPC Report

Energy rating

Current: 29 F | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 29 F Current: 29 F 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 17 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 17 Current: 17 80 Potential: 80
Field Value
LMK KEY 0418-8029-7256-4856-2924
ADDRESS1 47, Crown Lane
ADDRESS2
ADDRESS3
POSTCODE BR2 9PG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 29
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2016-06-09
LOCAL AUTHORITY E09000006
CONSTITUENCY E14001137
COUNTY
LODGEMENT DATE 2016-06-10
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 17
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 618
ENERGY CONSUMPTION POTENTIAL 90
CO2 EMISSIONS CURRENT 12
CO2 EMISS CURR PER FLOOR AREA 105
CO2 EMISSIONS POTENTIAL 1.8
LIGHTING COST CURRENT 104
LIGHTING COST POTENTIAL 68
HEATING COST CURRENT 1939
HEATING COST POTENTIAL 578
HOT WATER COST CURRENT 112
HOT WATER COST POTENTIAL 78
TOTAL FLOOR AREA 115
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 64
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Gas multipoint
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 64% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.77
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 47, Crown Lane
LOCAL AUTHORITY LABEL Bromley
CONSTITUENCY LABEL Bromley and Biggin Hill
POSTTOWN BROMLEY
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2016-06-10 09:08:17
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 100020395560
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000007
Address display
Nation ew