Energy Performance Certificate

11, Crowhurst Close, Carlton Colville, NR33 8SB

EPC Report

Energy rating

Current: 53 E | Potential: 88 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 53 E Current: 53 E 88 B Potential: 88 B

Environmental impact (CO₂)

Current: 49 | Potential: 90
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 49 Current: 49 90 Potential: 90
Field Value
LMK KEY 0417-2829-7981-9827-6901
ADDRESS1 11, Crowhurst Close
ADDRESS2 Carlton Colville
ADDRESS3
POSTCODE NR33 8SB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 53
POTENTIAL ENERGY EFFICIENCY 88
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2013-08-21
LOCAL AUTHORITY E07000244
CONSTITUENCY E14001344
COUNTY
LODGEMENT DATE 2013-08-21
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 49
ENVIRONMENT IMPACT POTENTIAL 90
ENERGY CONSUMPTION CURRENT 328
ENERGY CONSUMPTION POTENTIAL 56
CO2 EMISSIONS CURRENT 4.4
CO2 EMISS CURR PER FLOOR AREA 63
CO2 EMISSIONS POTENTIAL 0.8
LIGHTING COST CURRENT 42
LIGHTING COST POTENTIAL 42
HEATING COST CURRENT 578
HEATING COST POTENTIAL 344
HOT WATER COST CURRENT 320
HOT WATER COST POTENTIAL 77
TOTAL FLOOR AREA 69
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Room thermostat only
MULTI GLAZE PROPORTION 0
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Room thermostat only
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 11, Crowhurst Close, Carlton Colville
LOCAL AUTHORITY LABEL East Suffolk
CONSTITUENCY LABEL Lowestoft
POSTTOWN LOWESTOFT
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2013-08-21 15:53:25
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 100091164725
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000006
Address display
Nation ew