Energy Performance Certificate

2 Victoria Terrace, Stryd y Ffynnon, Nefyn, LL53 6HW

EPC Report

Energy rating

Current: 25 F | Potential: 39 E
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 25 F Current: 25 F 39 E Potential: 39 E

Environmental impact (CO₂)

Current: 32 | Potential: 42
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 32 Current: 32 42 Potential: 42
Field Value
LMK KEY 0417-2817-7088-2800-7755
ADDRESS1 2 Victoria Terrace
ADDRESS2 Stryd y Ffynnon
ADDRESS3 Nefyn
POSTCODE LL53 6HW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING E
CURRENT ENERGY EFFICIENCY 25
POTENTIAL ENERGY EFFICIENCY 39
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2020-08-03
LOCAL AUTHORITY W06000002
CONSTITUENCY W07000096
COUNTY
LODGEMENT DATE 2020-08-04
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 32
ENVIRONMENT IMPACT POTENTIAL 42
ENERGY CONSUMPTION CURRENT 452
ENERGY CONSUMPTION POTENTIAL 341
CO2 EMISSIONS CURRENT 9.3
CO2 EMISS CURR PER FLOOR AREA 83
CO2 EMISSIONS POTENTIAL 7.2
LIGHTING COST CURRENT 165
LIGHTING COST POTENTIAL 83
HEATING COST CURRENT 2220
HEATING COST POTENTIAL 2173
HOT WATER COST CURRENT 666
HOT WATER COST POTENTIAL 399
TOTAL FLOOR AREA 113
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION No system present: electric immersion assumed
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Granite or whinstone, with internal insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.62
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 2 Victoria Terrace, Stryd y Ffynnon, Nefyn
LOCAL AUTHORITY LABEL Gwynedd
CONSTITUENCY LABEL Dwyfor Meirionnydd
POSTTOWN PWLLHELI
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2020-08-04 08:54:58
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 10070347407
UPRN SOURCE Address Matched
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew