Energy Performance Certificate

47, Burnthurst Crescent, Shirley, B90 4UJ

EPC Report

Energy rating

Current: 52 E | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 52 E Current: 52 E 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 47 | Potential: 76
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 47 Current: 47 76 Potential: 76
Field Value
LMK KEY 0414-2898-7180-9624-7095
ADDRESS1 47, Burnthurst Crescent
ADDRESS2 Shirley
ADDRESS3
POSTCODE B90 4UJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 52
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2014-08-28
LOCAL AUTHORITY E08000029
CONSTITUENCY E14001479
COUNTY
LODGEMENT DATE 2014-08-28
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 47
ENVIRONMENT IMPACT POTENTIAL 76
ENERGY CONSUMPTION CURRENT 287
ENERGY CONSUMPTION POTENTIAL 124
CO2 EMISSIONS CURRENT 6.5
CO2 EMISS CURR PER FLOOR AREA 55
CO2 EMISSIONS POTENTIAL 2.9
LIGHTING COST CURRENT 121
LIGHTING COST POTENTIAL 66
HEATING COST CURRENT 1234
HEATING COST POTENTIAL 733
HOT WATER COST CURRENT 122
HOT WATER COST POTENTIAL 108
TOTAL FLOOR AREA 117
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 17
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, limited insulation (assumed)
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 17% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.71
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 47, Burnthurst Crescent, Shirley
LOCAL AUTHORITY LABEL Solihull
CONSTITUENCY LABEL Solihull West and Shirley
POSTTOWN SOLIHULL
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2014-08-28 11:58:33
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 100070981396
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000005
Address display
Nation ew