Energy Performance Certificate

26, The Grove, CF44 7NA

EPC Report

Energy rating

Current: 1 G | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 1 G Current: 1 G 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 6 | Potential: 88
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 6 Current: 6 88 Potential: 88
Field Value
LMK KEY 0411-2896-7028-9424-9495
ADDRESS1 26, The Grove
ADDRESS2
ADDRESS3
POSTCODE CF44 7NA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 1
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2014-02-26
LOCAL AUTHORITY W06000016
CONSTITUENCY W07000099
COUNTY
LODGEMENT DATE 2014-02-28
TRANSACTION TYPE FiT application
ENVIRONMENT IMPACT CURRENT 6
ENVIRONMENT IMPACT POTENTIAL 88
ENERGY CONSUMPTION CURRENT 940
ENERGY CONSUMPTION POTENTIAL 55
CO2 EMISSIONS CURRENT 12
CO2 EMISS CURR PER FLOOR AREA 166
CO2 EMISSIONS POTENTIAL 0.8
LIGHTING COST CURRENT 89
LIGHTING COST POTENTIAL 45
HEATING COST CURRENT 2691
HEATING COST POTENTIAL 366
HOT WATER COST CURRENT 471
HOT WATER COST POTENTIAL 72
TOTAL FLOOR AREA 72
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS None
MULTI GLAZE PROPORTION 0
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION No system present: electric immersion assumed
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL To be used only when there is no heating/hot-water system
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.544
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 26, The Grove
LOCAL AUTHORITY LABEL Rhondda Cynon Taf
CONSTITUENCY LABEL Merthyr Tydfil and Aberdare
POSTTOWN ABERDARE
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2014-02-28 01:11:47
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100100701746
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew