Energy Performance Certificate

20 Chesil Street, SO23 0HU

EPC Report

Energy rating

Current: 40 E | Potential: 59 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 40 E Current: 40 E 59 D Potential: 59 D

Environmental impact (CO₂)

Current: 47 | Potential: 63
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 47 Current: 47 63 Potential: 63
Field Value
LMK KEY 0410-3920-1200-5344-2200
ADDRESS1 20 Chesil Street
ADDRESS2
ADDRESS3
POSTCODE SO23 0HU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 40
POTENTIAL ENERGY EFFICIENCY 59
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2024-10-09
LOCAL AUTHORITY E07000094
CONSTITUENCY E14001587
COUNTY
LODGEMENT DATE 2024-10-10
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 47
ENVIRONMENT IMPACT POTENTIAL 63
ENERGY CONSUMPTION CURRENT 312
ENERGY CONSUMPTION POTENTIAL 198
CO2 EMISSIONS CURRENT 5.1
CO2 EMISS CURR PER FLOOR AREA 53
CO2 EMISSIONS POTENTIAL 3.2
LIGHTING COST CURRENT 106
LIGHTING COST POTENTIAL 106
HEATING COST CURRENT 1860
HEATING COST POTENTIAL 1709
HOT WATER COST CURRENT 503
HOT WATER COST POTENTIAL 226
TOTAL FLOOR AREA 97
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Less Than Typical
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, insulated
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and underfloor heating, electric, Boiler and radiators, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.38
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 20 Chesil Street
LOCAL AUTHORITY LABEL Winchester
CONSTITUENCY LABEL Winchester
POSTTOWN WINCHESTER
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2024-10-10 11:15:52
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 18
LOW ENERGY FIXED LIGHT COUNT 18
UPRN 100060598938
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000008
Address display
Nation ew