Energy Performance Certificate

Talbot Court Farm, Tresham, GL12 7RW

EPC Report

Energy rating

Current: 58 D | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 D Current: 58 D 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 62 | Potential: 81
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 62 Current: 62 81 Potential: 81
Field Value
LMK KEY 0410-2867-7432-9503-0301
ADDRESS1 Talbot Court Farm
ADDRESS2 Tresham
ADDRESS3
POSTCODE GL12 7RW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 58
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2017-07-03
LOCAL AUTHORITY E07000082
CONSTITUENCY E14001482
COUNTY
LODGEMENT DATE 2017-07-26
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 62
ENVIRONMENT IMPACT POTENTIAL 81
ENERGY CONSUMPTION CURRENT 200
ENERGY CONSUMPTION POTENTIAL 101
CO2 EMISSIONS CURRENT 12
CO2 EMISS CURR PER FLOOR AREA 30
CO2 EMISSIONS POTENTIAL 5.9
LIGHTING COST CURRENT 168
LIGHTING COST POTENTIAL 168
HEATING COST CURRENT 3392
HEATING COST POTENTIAL 2337
HOT WATER COST CURRENT 157
HOT WATER COST POTENTIAL 157
TOTAL FLOOR AREA 396
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 91
GLAZED TYPE not defined
GLAZED AREA Much More Than Typical
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 10
NUMBER HEATED ROOMS 10
LOW ENERGY LIGHTING 89
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly multiple glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Sandstone or limestone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Roof room(s), insulated
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Ground source heat pump, radiators, electric, Ground source heat pump, radiators, electric
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in 89% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Talbot Court Farm, Tresham
LOCAL AUTHORITY LABEL Stroud
CONSTITUENCY LABEL South Cotswolds
POSTTOWN WOTTON-UNDER-EDGE
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2017-07-26 11:54:12
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 27
LOW ENERGY FIXED LIGHT COUNT 24
UPRN 10009409733
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000009
Address display
Nation ew