Energy Performance Certificate

7, Upper Mount, Meltham, HD9 4AZ

EPC Report

Energy rating

Current: 48 E | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 E Current: 48 E 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 45 | Potential: 84
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 45 Current: 45 84 Potential: 84
Field Value
LMK KEY 0408-2872-7153-9907-6701
ADDRESS1 7, Upper Mount
ADDRESS2 Meltham
ADDRESS3
POSTCODE HD9 4AZ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 48
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2013-05-02
LOCAL AUTHORITY E08000034
CONSTITUENCY E14001177
COUNTY
LODGEMENT DATE 2013-05-03
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 45
ENVIRONMENT IMPACT POTENTIAL 84
ENERGY CONSUMPTION CURRENT 365
ENERGY CONSUMPTION POTENTIAL 100
CO2 EMISSIONS CURRENT 4.9
CO2 EMISS CURR PER FLOOR AREA 71
CO2 EMISSIONS POTENTIAL 1.4
LIGHTING COST CURRENT 88
LIGHTING COST POTENTIAL 44
HEATING COST CURRENT 858
HEATING COST POTENTIAL 473
HOT WATER COST CURRENT 94
HOT WATER COST POTENTIAL 59
TOTAL FLOOR AREA 69
ENERGY TARIFF dual
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 85
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Sandstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 25 mm loft insulation
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.51
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 7, Upper Mount, Meltham
LOCAL AUTHORITY LABEL Kirklees
CONSTITUENCY LABEL Colne Valley
POSTTOWN HOLMFIRTH
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2013-05-03 16:25:48
TENURE Rented (private)
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 83011219
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000003
Address display
Nation ew