Energy Performance Certificate

2, Brean Walk, Earley, RG6 5XD

EPC Report

Energy rating

Current: 44 E | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 44 E Current: 44 E 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 48 | Potential: 83
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 Current: 48 83 Potential: 83
Field Value
LMK KEY 0406-2872-7846-9427-5805
ADDRESS1 2, Brean Walk
ADDRESS2 Earley
ADDRESS3
POSTCODE RG6 5XD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 44
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2013-04-22
LOCAL AUTHORITY E06000041
CONSTITUENCY E14001210
COUNTY
LODGEMENT DATE 2013-04-22
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 48
ENVIRONMENT IMPACT POTENTIAL 83
ENERGY CONSUMPTION CURRENT 314
ENERGY CONSUMPTION POTENTIAL 100
CO2 EMISSIONS CURRENT 7.0
CO2 EMISS CURR PER FLOOR AREA 50
CO2 EMISSIONS POTENTIAL 2.1
LIGHTING COST CURRENT 130
LIGHTING COST POTENTIAL 66
HEATING COST CURRENT 1468
HEATING COST POTENTIAL 695
HOT WATER COST CURRENT 120
HOT WATER COST POTENTIAL 68
TOTAL FLOOR AREA 141
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 0
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 75 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.32
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 2, Brean Walk, Earley
LOCAL AUTHORITY LABEL Wokingham
CONSTITUENCY LABEL Earley and Woodley
POSTTOWN READING
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2013-04-22 14:17:41
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 17
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 14014953
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000008
Address display
Nation ew