Energy Performance Certificate

7, Brookside Road, Breadsall, DE21 5LF

EPC Report

Energy rating

Current: 36 F | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 36 F Current: 36 F 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 32 | Potential: 76
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 32 Current: 32 76 Potential: 76
Field Value
LMK KEY 0404-2852-7120-9327-7935
ADDRESS1 7, Brookside Road
ADDRESS2 Breadsall
ADDRESS3
POSTCODE DE21 5LF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 36
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2013-02-22
LOCAL AUTHORITY E07000036
CONSTITUENCY E14001362
COUNTY
LODGEMENT DATE 2013-02-23
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 32
ENVIRONMENT IMPACT POTENTIAL 76
ENERGY CONSUMPTION CURRENT 375
ENERGY CONSUMPTION POTENTIAL 112
CO2 EMISSIONS CURRENT 11
CO2 EMISS CURR PER FLOOR AREA 73
CO2 EMISSIONS POTENTIAL 3.5
LIGHTING COST CURRENT 144
LIGHTING COST POTENTIAL 77
HEATING COST CURRENT 1933
HEATING COST POTENTIAL 755
HOT WATER COST CURRENT 120
HOT WATER COST POTENTIAL 95
TOTAL FLOOR AREA 158
ENERGY TARIFF dual
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS TRVs and bypass
MULTI GLAZE PROPORTION 0
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 9
NUMBER OPEN FIREPLACES 2
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Roof room(s), no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 9% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.06
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 7, Brookside Road, Breadsall
LOCAL AUTHORITY LABEL Erewash
CONSTITUENCY LABEL Mid Derbyshire
POSTTOWN DERBY
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2013-02-23 11:50:05
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 22
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 100030119609
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000004
Address display
Nation ew