Energy Performance Certificate

2 NORTH CRAY ROAD, BEXLEY, DA5 3LZ

EPC Report

Energy rating

Current: 70 C | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 70 C Current: 70 C 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 64 | Potential: 78
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 Current: 64 78 Potential: 78
Field Value
LMK KEY 0403-2159-6002-1899-1302
ADDRESS1 2 NORTH CRAY ROAD
ADDRESS2 BEXLEY
ADDRESS3
POSTCODE DA5 3LZ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 70
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2021-01-14
LOCAL AUTHORITY E09000004
CONSTITUENCY E14001414
COUNTY
LODGEMENT DATE 2021-01-14
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 64
ENVIRONMENT IMPACT POTENTIAL 78
ENERGY CONSUMPTION CURRENT 166
ENERGY CONSUMPTION POTENTIAL 93
CO2 EMISSIONS CURRENT 5.8
CO2 EMISS CURR PER FLOOR AREA 29
CO2 EMISSIONS POTENTIAL 3.3
LIGHTING COST CURRENT 130
LIGHTING COST POTENTIAL 130
HEATING COST CURRENT 1008
HEATING COST POTENTIAL 721
HOT WATER COST CURRENT 94
HOT WATER COST POTENTIAL 94
TOTAL FLOOR AREA 198
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 75
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 82
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 82% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.38
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 2 NORTH CRAY ROAD, BEXLEY
LOCAL AUTHORITY LABEL Bexley
CONSTITUENCY LABEL Old Bexley and Sidcup
POSTTOWN BEXLEY
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2021-01-14 21:50:26
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 17
LOW ENERGY FIXED LIGHT COUNT 14
UPRN 10011862033
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000007
Address display
Nation ew