Energy Performance Certificate

Harlyn, Beulah, SA38 9QB

EPC Report

Energy rating

Current: 51 E | Potential: 74 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 51 E Current: 51 E 74 C Potential: 74 C

Environmental impact (CO₂)

Current: 43 | Potential: 66
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 43 Current: 43 66 Potential: 66
Field Value
LMK KEY 0400-4964-0022-8028-0893
ADDRESS1 Harlyn
ADDRESS2 Beulah
ADDRESS3
POSTCODE SA38 9QB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 51
POTENTIAL ENERGY EFFICIENCY 74
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2021-08-26
LOCAL AUTHORITY W06000008
CONSTITUENCY W07000093
COUNTY
LODGEMENT DATE 2021-09-02
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 43
ENVIRONMENT IMPACT POTENTIAL 66
ENERGY CONSUMPTION CURRENT 222
ENERGY CONSUMPTION POTENTIAL 109
CO2 EMISSIONS CURRENT 8.2
CO2 EMISS CURR PER FLOOR AREA 58
CO2 EMISSIONS POTENTIAL 4.6
LIGHTING COST CURRENT 176
LIGHTING COST POTENTIAL 97
HEATING COST CURRENT 928
HEATING COST POTENTIAL 618
HOT WATER COST CURRENT 179
HOT WATER COST POTENTIAL 145
TOTAL FLOOR AREA 142
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 18
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 18% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.6
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Harlyn, Beulah
LOCAL AUTHORITY LABEL Ceredigion
CONSTITUENCY LABEL Ceredigion Preseli
POSTTOWN NEWCASTLE EMLYN
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2021-09-02 12:28:34
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 49048001
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew