Energy Performance Certificate

102, King Edward Road, SK14 5JJ

EPC Report

Energy rating

Current: 65 D | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 D Current: 65 D 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 64 | Potential: 88
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 Current: 64 88 Potential: 88
Field Value
LMK KEY 0398-6033-7218-2164-3920
ADDRESS1 102, King Edward Road
ADDRESS2
ADDRESS3
POSTCODE SK14 5JJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 65
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2014-08-01
LOCAL AUTHORITY E08000008
CONSTITUENCY E14001515
COUNTY
LODGEMENT DATE 2014-08-01
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 64
ENVIRONMENT IMPACT POTENTIAL 88
ENERGY CONSUMPTION CURRENT 226
ENERGY CONSUMPTION POTENTIAL 76
CO2 EMISSIONS CURRENT
CO2 EMISS CURR PER FLOOR AREA
CO2 EMISSIONS POTENTIAL
LIGHTING COST CURRENT 52
LIGHTING COST POTENTIAL 52
HEATING COST CURRENT 508
HEATING COST POTENTIAL 397
HOT WATER COST CURRENT 133
HOT WATER COST POTENTIAL 71
TOTAL FLOOR AREA 66
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 75
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300+ mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 75% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.6
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 102, King Edward Road
LOCAL AUTHORITY LABEL Tameside
CONSTITUENCY LABEL Stalybridge and Hyde
POSTTOWN HYDE
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2014-08-01 16:50:48
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100011574790
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000002
Address display
Nation ew