Energy Performance Certificate

5 Upper Hollow, Littleover, DE23 6GJ

EPC Report

Energy rating

Current: 23 F | Potential: 76 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 23 F Current: 23 F 76 C Potential: 76 C

Environmental impact (CO₂)

Current: 17 | Potential: 69
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 17 Current: 17 69 Potential: 69
Field Value
LMK KEY 0396-1003-6232-4277-6200
ADDRESS1 5 Upper Hollow
ADDRESS2 Littleover
ADDRESS3
POSTCODE DE23 6GJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 23
POTENTIAL ENERGY EFFICIENCY 76
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2023-02-01
LOCAL AUTHORITY E06000015
CONSTITUENCY E14001193
COUNTY
LODGEMENT DATE 2023-02-01
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 17
ENVIRONMENT IMPACT POTENTIAL 69
ENERGY CONSUMPTION CURRENT 545
ENERGY CONSUMPTION POTENTIAL 144
CO2 EMISSIONS CURRENT 21
CO2 EMISS CURR PER FLOOR AREA 98
CO2 EMISSIONS POTENTIAL 5.5
LIGHTING COST CURRENT 126
LIGHTING COST POTENTIAL 129
HEATING COST CURRENT 3391
HEATING COST POTENTIAL 1152
HOT WATER COST CURRENT 351
HOT WATER COST POTENTIAL 76
TOTAL FLOOR AREA 210
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, no room thermostat
MULTI GLAZE PROPORTION 18
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 4
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION To unheated space, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, no room thermostat
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 3.1
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 5 Upper Hollow, Littleover
LOCAL AUTHORITY LABEL Derby
CONSTITUENCY LABEL Derby North
POSTTOWN DERBY
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2023-02-01 21:57:20
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 34
LOW ENERGY FIXED LIGHT COUNT 34
UPRN 100030367466
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000004
Address display
Nation ew