Energy Performance Certificate

4 The Green, Lyford, OX12 0EG

EPC Report

Energy rating

Current: 20 G | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 20 G Current: 20 G 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 3 | Potential: 50
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 3 Current: 3 50 Potential: 50
Field Value
LMK KEY 0395-2858-6941-9505-7331
ADDRESS1 4 The Green
ADDRESS2 Lyford
ADDRESS3
POSTCODE OX12 0EG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 20
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2015-04-08
LOCAL AUTHORITY E07000180
CONSTITUENCY E14001591
COUNTY
LODGEMENT DATE 2015-04-08
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 3
ENVIRONMENT IMPACT POTENTIAL 50
ENERGY CONSUMPTION CURRENT 1050
ENERGY CONSUMPTION POTENTIAL 330
CO2 EMISSIONS CURRENT 13
CO2 EMISS CURR PER FLOOR AREA 185
CO2 EMISSIONS POTENTIAL 4.1
LIGHTING COST CURRENT 74
LIGHTING COST POTENTIAL 52
HEATING COST CURRENT 1666
HEATING COST POTENTIAL 602
HOT WATER COST CURRENT 184
HOT WATER COST POTENTIAL 86
TOTAL FLOOR AREA 72
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 57
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Granite or whinstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 57% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.03
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 4 The Green, Lyford
LOCAL AUTHORITY LABEL Vale of White Horse
CONSTITUENCY LABEL Witney
POSTTOWN WANTAGE
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2015-04-08 07:46:58
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 10014027631
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000008
Address display
Nation ew