Energy Performance Certificate

26a, Bulbery, Abbotts Ann, SP11 7BN

EPC Report

Energy rating

Current: 53 E | Potential: 76 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 53 E Current: 53 E 76 C Potential: 76 C

Environmental impact (CO₂)

Current: 38 | Potential: 59
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 38 Current: 38 59 Potential: 59
Field Value
LMK KEY 0394-2843-6019-9808-8121
ADDRESS1 26a, Bulbery
ADDRESS2 Abbotts Ann
ADDRESS3
POSTCODE SP11 7BN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 53
POTENTIAL ENERGY EFFICIENCY 76
PROPERTY TYPE Maisonette
BUILT FORM Detached
INSPECTION DATE 2018-09-07
LOCAL AUTHORITY E07000093
CONSTITUENCY E14001449
COUNTY
LODGEMENT DATE 2018-09-07
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 38
ENVIRONMENT IMPACT POTENTIAL 59
ENERGY CONSUMPTION CURRENT 565
ENERGY CONSUMPTION POTENTIAL 340
CO2 EMISSIONS CURRENT 4.4
CO2 EMISS CURR PER FLOOR AREA 96
CO2 EMISSIONS POTENTIAL 2.7
LIGHTING COST CURRENT 65
LIGHTING COST POTENTIAL 41
HEATING COST CURRENT 625
HEATING COST POTENTIAL 283
HOT WATER COST CURRENT 225
HOT WATER COST POTENTIAL 139
TOTAL FLOOR AREA 46
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 42
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 42% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 26a, Bulbery, Abbotts Ann
LOCAL AUTHORITY LABEL Test Valley
CONSTITUENCY LABEL Romsey and Southampton North
POSTTOWN ANDOVER
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2018-09-07 15:27:14
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100060555347
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000008
Address display
Nation ew