Energy Performance Certificate

35 CATHCART CLOSE, WHITLEY, DN14 0JE

EPC Report

Energy rating

Current: 86 B | Potential: 119 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 86 B Current: 86 B 119 A Potential: 119 A

Environmental impact (CO₂)

Current: 96 | Potential: 104
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 96 Current: 96 104 Potential: 104
Field Value
LMK KEY 0390-2902-8020-2796-5835
ADDRESS1 35 CATHCART CLOSE
ADDRESS2 WHITLEY
ADDRESS3
POSTCODE DN14 0JE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 86
POTENTIAL ENERGY EFFICIENCY 119
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2026-02-12
LOCAL AUTHORITY E06000065
CONSTITUENCY E14001464
COUNTY
LODGEMENT DATE 2026-02-13
TRANSACTION TYPE Grant scheme
ENVIRONMENT IMPACT CURRENT 96
ENVIRONMENT IMPACT POTENTIAL 104
ENERGY CONSUMPTION CURRENT 54
ENERGY CONSUMPTION POTENTIAL -17
CO2 EMISSIONS CURRENT 0.3
CO2 EMISS CURR PER FLOOR AREA 5
CO2 EMISSIONS POTENTIAL -0.3
LIGHTING COST CURRENT 54
LIGHTING COST POTENTIAL 54
HEATING COST CURRENT 752
HEATING COST POTENTIAL 794
HOT WATER COST CURRENT 384
HOT WATER COST POTENTIAL 432
TOTAL FLOOR AREA 65
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, limited insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Air source heat pump, radiators, electric
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Good lighting efficiency
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.36
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 35 CATHCART CLOSE, WHITLEY
LOCAL AUTHORITY LABEL North Yorkshire
CONSTITUENCY LABEL Selby
POSTTOWN GOOLE
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2026-02-13 15:50:48
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 100050503708
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2026.csv
COUNTRY England
REGION E12000003
Address display
Nation ew