Energy Performance Certificate

135 Wilmot Street, E2 0BU

EPC Report

Energy rating

Current: 39 E | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 39 E Current: 39 E 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 23 | Potential: 65
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 23 Current: 23 65 Potential: 65
Field Value
LMK KEY 0390-2562-9150-2292-3651
ADDRESS1 135 Wilmot Street
ADDRESS2
ADDRESS3
POSTCODE E2 0BU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 39
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2022-05-12
LOCAL AUTHORITY E09000030
CONSTITUENCY E14001086
COUNTY
LODGEMENT DATE 2022-05-13
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 23
ENVIRONMENT IMPACT POTENTIAL 65
ENERGY CONSUMPTION CURRENT 592
ENERGY CONSUMPTION POTENTIAL 212
CO2 EMISSIONS CURRENT 7.3
CO2 EMISS CURR PER FLOOR AREA 100
CO2 EMISSIONS POTENTIAL 2.6
LIGHTING COST CURRENT 99
LIGHTING COST POTENTIAL 72
HEATING COST CURRENT 1371
HEATING COST POTENTIAL 313
HOT WATER COST CURRENT 198
HOT WATER COST POTENTIAL 198
TOTAL FLOOR AREA 73
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 63
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Flat, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 63% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 8
FLOOR HEIGHT 2.32
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 135 Wilmot Street
LOCAL AUTHORITY LABEL Tower Hamlets
CONSTITUENCY LABEL Bethnal Green and Stepney
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2022-05-13 08:52:57
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 6017803
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000007
Address display
Nation ew