Energy rating

Current: 10 G | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 10 G Current: 10 G 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 24 | Potential: 60
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 24 Current: 24 60 Potential: 60
Field Value
LMK KEY 0388-9013-7219-3815-3914
ADDRESS1 The Cottage
ADDRESS2 38 Church Street
ADDRESS3
POSTCODE TQ3 3AH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 10
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2015-01-08
LOCAL AUTHORITY E06000027
CONSTITUENCY E14001551
COUNTY
LODGEMENT DATE 2015-01-10
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 24
ENVIRONMENT IMPACT POTENTIAL 60
ENERGY CONSUMPTION CURRENT 805
ENERGY CONSUMPTION POTENTIAL 299
CO2 EMISSIONS CURRENT 5.7
CO2 EMISS CURR PER FLOOR AREA 136
CO2 EMISSIONS POTENTIAL 2.1
LIGHTING COST CURRENT 44
LIGHTING COST POTENTIAL 49
HEATING COST CURRENT 1327
HEATING COST POTENTIAL 386
HOT WATER COST CURRENT 257
HOT WATER COST POTENTIAL 68
TOTAL FLOOR AREA 42
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS None
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING 50
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Sandstone or limestone, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 50% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL To be used only when there is no heating/hot-water system or data is from a community network
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS The Cottage, 38 Church Street
LOCAL AUTHORITY LABEL Torbay
CONSTITUENCY LABEL Torbay
POSTTOWN PAIGNTON
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2015-01-10 11:36:25
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 6