Energy Performance Certificate

1, Laundry Road, Apethorpe, PE8 5DQ

EPC Report

Energy rating

Current: 17 G | Potential: 91 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 17 G Current: 17 G 91 B Potential: 91 B

Environmental impact (CO₂)

Current: 16 | Potential: 86
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 16 Current: 16 86 Potential: 86
Field Value
LMK KEY 0388-4020-7211-5133-5980
ADDRESS1 1, Laundry Road
ADDRESS2 Apethorpe
ADDRESS3
POSTCODE PE8 5DQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 17
POTENTIAL ENERGY EFFICIENCY 91
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2017-09-08
LOCAL AUTHORITY E06000061
CONSTITUENCY E14001179
COUNTY
LODGEMENT DATE 2017-09-08
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 16
ENVIRONMENT IMPACT POTENTIAL 86
ENERGY CONSUMPTION CURRENT 523
ENERGY CONSUMPTION POTENTIAL 37
CO2 EMISSIONS CURRENT 9.9
CO2 EMISS CURR PER FLOOR AREA 138
CO2 EMISSIONS POTENTIAL 1.1
LIGHTING COST CURRENT 90
LIGHTING COST POTENTIAL 50
HEATING COST CURRENT 949
HEATING COST POTENTIAL 202
HOT WATER COST CURRENT 328
HOT WATER COST POTENTIAL 72
TOTAL FLOOR AREA 72
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 18
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Sandstone or limestone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Roof room(s), no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 18% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 1, Laundry Road, Apethorpe
LOCAL AUTHORITY LABEL North Northamptonshire
CONSTITUENCY LABEL Corby and East Northamptonshire
POSTTOWN PETERBOROUGH
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2017-09-08 16:53:07
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 100031025665
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000004
Address display
Nation ew