Energy Performance Certificate

26 HAWKESBURY MEWS, DL3 6RR

EPC Report

Energy rating

Current: 70 C | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 70 C Current: 70 C 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 61 | Potential: 65
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 61 Current: 61 65 Potential: 65
Field Value
LMK KEY 0380-2964-2050-2529-4615
ADDRESS1 26 HAWKESBURY MEWS
ADDRESS2
ADDRESS3
POSTCODE DL3 6RR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 70
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2021-05-24
LOCAL AUTHORITY E06000005
CONSTITUENCY E14001190
COUNTY
LODGEMENT DATE 2021-05-25
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 61
ENVIRONMENT IMPACT POTENTIAL 65
ENERGY CONSUMPTION CURRENT 299
ENERGY CONSUMPTION POTENTIAL 269
CO2 EMISSIONS CURRENT 3.3
CO2 EMISS CURR PER FLOOR AREA 51
CO2 EMISSIONS POTENTIAL 3.0
LIGHTING COST CURRENT 71
LIGHTING COST POTENTIAL 71
HEATING COST CURRENT 431
HEATING COST POTENTIAL 340
HOT WATER COST CURRENT 333
HOT WATER COST POTENTIAL 181
TOTAL FLOOR AREA 65
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 92
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 92% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 5.53
FLOOR HEIGHT 2.21
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 26 HAWKESBURY MEWS
LOCAL AUTHORITY LABEL Darlington
CONSTITUENCY LABEL Darlington
POSTTOWN DARLINGTON
CONSTRUCTION AGE BAND England and Wales: 1991-1995
LODGEMENT DATETIME 2021-05-25 18:05:36
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 11
UPRN 200002721431
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000001
Address display
Nation ew