Energy Performance Certificate

14 Brook Street, Bampton, EX16 9LY

EPC Report

Energy rating

Current: 27 F | Potential: 73 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 27 F Current: 27 F 73 C Potential: 73 C

Environmental impact (CO₂)

Current: 26 | Potential: 67
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 26 Current: 26 67 Potential: 67
Field Value
LMK KEY 0380-2758-9130-2722-2865
ADDRESS1 14 Brook Street
ADDRESS2 Bampton
ADDRESS3
POSTCODE EX16 9LY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 27
POTENTIAL ENERGY EFFICIENCY 73
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2022-07-28
LOCAL AUTHORITY E07000042
CONSTITUENCY E14001548
COUNTY
LODGEMENT DATE 2022-07-28
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 26
ENVIRONMENT IMPACT POTENTIAL 67
ENERGY CONSUMPTION CURRENT 444
ENERGY CONSUMPTION POTENTIAL 144
CO2 EMISSIONS CURRENT 9.1
CO2 EMISS CURR PER FLOOR AREA 91
CO2 EMISSIONS POTENTIAL 3.1
LIGHTING COST CURRENT 96
LIGHTING COST POTENTIAL 98
HEATING COST CURRENT 1837
HEATING COST POTENTIAL 789
HOT WATER COST CURRENT 393
HOT WATER COST POTENTIAL 177
TOTAL FLOOR AREA 100
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Much Less Than Typical
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 88
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Granite or whinstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 75 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 88% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL dual fuel - mineral + wood
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 14 Brook Street, Bampton
LOCAL AUTHORITY LABEL Mid Devon
CONSTITUENCY LABEL Tiverton and Minehead
POSTTOWN TIVERTON
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2022-07-28 14:13:16
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 100040361831
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000009
Address display
Nation ew