Energy Performance Certificate

153 Northfield Road, PE1 3QF

EPC Report

Energy rating

Current: 54 E | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 54 E Current: 54 E 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 47 | Potential: 82
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 47 Current: 47 82 Potential: 82
Field Value
LMK KEY 0380-2559-3370-2604-0861
ADDRESS1 153 Northfield Road
ADDRESS2
ADDRESS3
POSTCODE PE1 3QF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 54
POTENTIAL ENERGY EFFICIENCY 85
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2024-03-01
LOCAL AUTHORITY E06000031
CONSTITUENCY E14001425
COUNTY
LODGEMENT DATE 2024-06-04
TRANSACTION TYPE Stock condition survey
ENVIRONMENT IMPACT CURRENT 47
ENVIRONMENT IMPACT POTENTIAL 82
ENERGY CONSUMPTION CURRENT 348
ENERGY CONSUMPTION POTENTIAL 100
CO2 EMISSIONS CURRENT 5.1
CO2 EMISS CURR PER FLOOR AREA 61
CO2 EMISSIONS POTENTIAL 1.5
LIGHTING COST CURRENT 221
LIGHTING COST POTENTIAL 111
HEATING COST CURRENT 1621
HEATING COST POTENTIAL 824
HOT WATER COST CURRENT 169
HOT WATER COST POTENTIAL 112
TOTAL FLOOR AREA 83
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 80
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 270 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.66
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 153 Northfield Road
LOCAL AUTHORITY LABEL Peterborough
CONSTITUENCY LABEL Peterborough
POSTTOWN PETERBOROUGH
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2024-06-04 14:01:58
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 16
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100090210927
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000006
Address display
Nation ew