Energy Performance Certificate

35 Rother View Road, S60 2UW

EPC Report

Energy rating

Current: 79 C | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 79 C Current: 79 C 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 85 | Potential: 86
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 85 Current: 85 86 Potential: 86
Field Value
LMK KEY 0380-2161-4530-2425-3531
ADDRESS1 35 Rother View Road
ADDRESS2
ADDRESS3
POSTCODE S60 2UW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 79
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2025-07-29
LOCAL AUTHORITY E08000018
CONSTITUENCY E14001452
COUNTY
LODGEMENT DATE 2025-10-09
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 85
ENVIRONMENT IMPACT POTENTIAL 86
ENERGY CONSUMPTION CURRENT 91
ENERGY CONSUMPTION POTENTIAL 77
CO2 EMISSIONS CURRENT 1.3
CO2 EMISS CURR PER FLOOR AREA 15
CO2 EMISSIONS POTENTIAL 1.2
LIGHTING COST CURRENT 73
LIGHTING COST POTENTIAL 73
HEATING COST CURRENT 418
HEATING COST POTENTIAL 418
HOT WATER COST CURRENT 279
HOT WATER COST POTENTIAL 279
TOTAL FLOOR AREA 88
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 350 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Below average lighting efficiency
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.38
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 35 Rother View Road
LOCAL AUTHORITY LABEL Rotherham
CONSTITUENCY LABEL Rotherham
POSTTOWN ROTHERHAM
CONSTRUCTION AGE BAND England and Wales: 2012-2021
LODGEMENT DATETIME 2025-10-09 11:58:40
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 16
LOW ENERGY FIXED LIGHT COUNT 16
UPRN 10093481269
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000003
Address display
Nation ew