Energy Performance Certificate

1 Skylark Paddocks, East Yorkshire, YO25 4BB

EPC Report

Energy rating

Current: 85 B | Potential: 108 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 85 B Current: 85 B 108 A Potential: 108 A

Environmental impact (CO₂)

Current: 86 | Potential: 107
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 86 Current: 86 107 Potential: 107
Field Value
LMK KEY 0370-3149-8050-2507-6535
ADDRESS1 1 Skylark Paddocks
ADDRESS2
ADDRESS3 East Yorkshire
POSTCODE YO25 4BB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 85
POTENTIAL ENERGY EFFICIENCY 108
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2023-05-01
LOCAL AUTHORITY E06000011
CONSTITUENCY E14001127
COUNTY
LODGEMENT DATE 2023-05-01
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 86
ENVIRONMENT IMPACT POTENTIAL 107
ENERGY CONSUMPTION CURRENT 80
ENERGY CONSUMPTION POTENTIAL -43
CO2 EMISSIONS CURRENT 2.0
CO2 EMISS CURR PER FLOOR AREA 14
CO2 EMISSIONS POTENTIAL -1.1
LIGHTING COST CURRENT 192
LIGHTING COST POTENTIAL 192
HEATING COST CURRENT 733
HEATING COST POTENTIAL 734
HOT WATER COST CURRENT 493
HOT WATER COST POTENTIAL 304
TOTAL FLOOR AREA 148
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.16 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.18 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.10 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Air source heat pump, underfloor, electric
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Electricity: electricity, unspecified tariff
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.69
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 1 Skylark Paddocks, East Yorkshire
LOCAL AUTHORITY LABEL East Riding of Yorkshire
CONSTITUENCY LABEL Bridlington and The Wolds
POSTTOWN Kilham
CONSTRUCTION AGE BAND 2022
LODGEMENT DATETIME 2023-05-01 16:55:07
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 25
LOW ENERGY FIXED LIGHT COUNT 25
UPRN 10095945638
UPRN SOURCE Address Matched
REPORT TYPE 3
Source file certificates-2023.csv
COUNTRY England
REGION E12000003
Address display
Nation ew