Energy Performance Certificate

Ancillary Annexe At, 2 Hillside Road, CM0 8EY

EPC Report

Energy rating

Current: 54 E | Potential: 89 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 54 E Current: 54 E 89 B Potential: 89 B

Environmental impact (CO₂)

Current: 59 | Potential: 74
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 59 Current: 59 74 Potential: 74
Field Value
LMK KEY 0370-2986-4470-2225-1855
ADDRESS1 Ancillary Annexe At
ADDRESS2 2 Hillside Road
ADDRESS3
POSTCODE CM0 8EY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 54
POTENTIAL ENERGY EFFICIENCY 89
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2025-03-26
LOCAL AUTHORITY E07000074
CONSTITUENCY E14001351
COUNTY
LODGEMENT DATE 2025-03-28
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 59
ENVIRONMENT IMPACT POTENTIAL 74
ENERGY CONSUMPTION CURRENT 270
ENERGY CONSUMPTION POTENTIAL 152
CO2 EMISSIONS CURRENT 3.3
CO2 EMISS CURR PER FLOOR AREA 46
CO2 EMISSIONS POTENTIAL 1.9
LIGHTING COST CURRENT 84
LIGHTING COST POTENTIAL 95
HEATING COST CURRENT 967
HEATING COST POTENTIAL 584
HOT WATER COST CURRENT 497
HOT WATER COST POTENTIAL 155
TOTAL FLOOR AREA 73
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Timber frame, as built, insulated (assumed)
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Flat, insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Programmer and appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Ancillary Annexe At, 2 Hillside Road
LOCAL AUTHORITY LABEL Maldon
CONSTITUENCY LABEL Maldon
POSTTOWN BURNHAM-ON-CROUCH
CONSTRUCTION AGE BAND England and Wales: 2012 onwards
LODGEMENT DATETIME 2025-03-28 13:30:22
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 19
LOW ENERGY FIXED LIGHT COUNT 19
UPRN 10094637544
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000006
Address display
Nation ew