Energy Performance Certificate

2 Lime Grove, IP24 2HW

EPC Report

Energy rating

Current: 62 D | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 62 D Current: 62 D 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 84 | Potential: 94
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 84 Current: 84 94 Potential: 94
Field Value
LMK KEY 0370-2804-1530-2405-1275
ADDRESS1 2 Lime Grove
ADDRESS2
ADDRESS3
POSTCODE IP24 2HW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 62
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2025-07-04
LOCAL AUTHORITY E07000143
CONSTITUENCY E14001497
COUNTY
LODGEMENT DATE 2025-07-04
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 84
ENVIRONMENT IMPACT POTENTIAL 94
ENERGY CONSUMPTION CURRENT 237
ENERGY CONSUMPTION POTENTIAL 76
CO2 EMISSIONS CURRENT 1.1
CO2 EMISS CURR PER FLOOR AREA 22
CO2 EMISSIONS POTENTIAL 0.4
LIGHTING COST CURRENT 56
LIGHTING COST POTENTIAL 53
HEATING COST CURRENT 1139
HEATING COST POTENTIAL 750
HOT WATER COST CURRENT 364
HOT WATER COST POTENTIAL 319
TOTAL FLOOR AREA 53
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Solid, limited insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Below average lighting efficiency
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.36
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 2 Lime Grove
LOCAL AUTHORITY LABEL Breckland
CONSTITUENCY LABEL South West Norfolk
POSTTOWN THETFORD
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2025-07-04 15:11:09
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 10011957355
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000006
Address display
Nation ew