Energy Performance Certificate

11 Chequers Close, Briston, NR24 2PW

EPC Report

Energy rating

Current: 58 D | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 D Current: 58 D 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 50 | Potential: 69
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 50 Current: 50 69 Potential: 69
Field Value
LMK KEY 0370-2587-9550-2625-8015
ADDRESS1 11 Chequers Close
ADDRESS2 Briston
ADDRESS3
POSTCODE NR24 2PW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 58
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2025-05-23
LOCAL AUTHORITY E07000147
CONSTITUENCY E14001396
COUNTY
LODGEMENT DATE 2025-05-28
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 50
ENVIRONMENT IMPACT POTENTIAL 69
ENERGY CONSUMPTION CURRENT 218
ENERGY CONSUMPTION POTENTIAL 112
CO2 EMISSIONS CURRENT 5.3
CO2 EMISS CURR PER FLOOR AREA 57
CO2 EMISSIONS POTENTIAL 3.2
LIGHTING COST CURRENT 117
LIGHTING COST POTENTIAL 117
HEATING COST CURRENT 820
HEATING COST POTENTIAL 716
HOT WATER COST CURRENT 252
HOT WATER COST POTENTIAL 133
TOTAL FLOOR AREA 94
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE not defined
GLAZED AREA Much More Than Typical
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 94
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 94% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.36
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 11 Chequers Close, Briston
LOCAL AUTHORITY LABEL North Norfolk
CONSTITUENCY LABEL North Norfolk
POSTTOWN MELTON CONSTABLE
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2025-05-28 09:26:41
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 17
LOW ENERGY FIXED LIGHT COUNT 16
UPRN 100090871048
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000006
Address display
Nation ew