Energy Performance Certificate

1 Ferry View, Bowness-On-Windermere, LA23 3JB

EPC Report

Energy rating

Current: 79 C | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 79 C Current: 79 C 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 76 | Potential: 84
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 76 Current: 76 84 Potential: 84
Field Value
LMK KEY 0370-2515-8080-2229-5905
ADDRESS1 1 Ferry View
ADDRESS2 Bowness-On-Windermere
ADDRESS3
POSTCODE LA23 3JB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 79
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2021-08-25
LOCAL AUTHORITY E06000064
CONSTITUENCY E14001580
COUNTY
LODGEMENT DATE 2021-09-06
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 76
ENVIRONMENT IMPACT POTENTIAL 84
ENERGY CONSUMPTION CURRENT 135
ENERGY CONSUMPTION POTENTIAL 94
CO2 EMISSIONS CURRENT 4.0
CO2 EMISS CURR PER FLOOR AREA 24
CO2 EMISSIONS POTENTIAL 2.8
LIGHTING COST CURRENT 106
LIGHTING COST POTENTIAL 106
HEATING COST CURRENT 623
HEATING COST POTENTIAL 627
HOT WATER COST CURRENT 131
HOT WATER COST POTENTIAL 83
TOTAL FLOOR AREA 168
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double, known data
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, insulated
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Granite or whinstone, with internal insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Roof room(s), insulated
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 1 Ferry View, Bowness-On-Windermere
LOCAL AUTHORITY LABEL Westmorland and Furness
CONSTITUENCY LABEL Westmorland and Lonsdale
POSTTOWN WINDERMERE
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2021-09-06 13:21:38
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 30
LOW ENERGY FIXED LIGHT COUNT 30
UPRN 100110353161
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000002
Address display
Nation ew