Energy Performance Certificate

Thornbush, Lower Freystrop, SA62 4ET

EPC Report

Energy rating

Current: 1 G | Potential: 59 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 1 G Current: 1 G 59 D Potential: 59 D

Environmental impact (CO₂)

Current: 12 | Potential: 57
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 12 Current: 12 57 Potential: 57
Field Value
LMK KEY 0370-2500-1220-2227-7415
ADDRESS1 Thornbush
ADDRESS2 Lower Freystrop
ADDRESS3
POSTCODE SA62 4ET
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 1
POTENTIAL ENERGY EFFICIENCY 59
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2023-02-20
LOCAL AUTHORITY W06000009
CONSTITUENCY W07000100
COUNTY
LODGEMENT DATE 2023-02-20
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 12
ENVIRONMENT IMPACT POTENTIAL 57
ENERGY CONSUMPTION CURRENT 585
ENERGY CONSUMPTION POTENTIAL 185
CO2 EMISSIONS CURRENT 20
CO2 EMISS CURR PER FLOOR AREA 112
CO2 EMISSIONS POTENTIAL 6.3
LIGHTING COST CURRENT 266
LIGHTING COST POTENTIAL 266
HEATING COST CURRENT 9824
HEATING COST POTENTIAL 4990
HOT WATER COST CURRENT 1124
HOT WATER COST POTENTIAL 268
TOTAL FLOOR AREA 175
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 85
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 72
NUMBER OPEN FIREPLACES 2
HOTWATER DESCRIPTION Oil range cooker, no cylinder thermostat
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Sandstone or limestone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Portable electric heaters assumed for most rooms
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 72% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL dual fuel - mineral + wood
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.48
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Thornbush, Lower Freystrop
LOCAL AUTHORITY LABEL Pembrokeshire
CONSTITUENCY LABEL Mid and South Pembrokeshire
POSTTOWN HAVERFORDWEST
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2023-02-20 16:40:29
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 18
LOW ENERGY FIXED LIGHT COUNT 13
UPRN 10009881196
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY Wales
REGION W99999999
Address display