Energy Performance Certificate

41 Newbury Close, RM3 8HB

EPC Report

Energy rating

Current: 76 C | Potential: 95 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 76 C Current: 76 C 95 A Potential: 95 A

Environmental impact (CO₂)

Current: 78 | Potential: 95
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 78 Current: 78 95 Potential: 95
Field Value
LMK KEY 0370-2473-7350-2194-7861
ADDRESS1 41 Newbury Close
ADDRESS2
ADDRESS3
POSTCODE RM3 8HB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 76
POTENTIAL ENERGY EFFICIENCY 95
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2024-05-17
LOCAL AUTHORITY E09000016
CONSTITUENCY E14001292
COUNTY
LODGEMENT DATE 2024-05-20
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 78
ENVIRONMENT IMPACT POTENTIAL 95
ENERGY CONSUMPTION CURRENT 143
ENERGY CONSUMPTION POTENTIAL 24
CO2 EMISSIONS CURRENT 2.0
CO2 EMISS CURR PER FLOOR AREA 24
CO2 EMISSIONS POTENTIAL 0.3
LIGHTING COST CURRENT 110
LIGHTING COST POTENTIAL 110
HEATING COST CURRENT 449
HEATING COST POTENTIAL 390
HOT WATER COST CURRENT 632
HOT WATER COST POTENTIAL 263
TOTAL FLOOR AREA 82
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 90
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, with external insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Air source heat pump, radiators, electric
MAINHEAT ENERGY EFF Very Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.2
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 41 Newbury Close
LOCAL AUTHORITY LABEL Havering
CONSTITUENCY LABEL Hornchurch and Upminster
POSTTOWN ROMFORD
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2024-05-20 13:23:03
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 100021388846
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000007
Address display
Nation ew