Energy Performance Certificate

Flat 25, Elizabeth Court, 47 Milmans Street, SW10 0DA

EPC Report

Energy rating

Current: 51 E | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 51 E Current: 51 E 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 56 | Potential: 74
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 56 Current: 56 74 Potential: 74
Field Value
LMK KEY 0366-0021-7208-5909-7204
ADDRESS1 Flat 25
ADDRESS2 Elizabeth Court
ADDRESS3 47 Milmans Street
POSTCODE SW10 0DA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 51
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2021-08-06
LOCAL AUTHORITY E09000020
CONSTITUENCY E14001160
COUNTY
LODGEMENT DATE 2021-09-10
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 56
ENVIRONMENT IMPACT POTENTIAL 74
ENERGY CONSUMPTION CURRENT 340
ENERGY CONSUMPTION POTENTIAL 187
CO2 EMISSIONS CURRENT 3.0
CO2 EMISS CURR PER FLOOR AREA 58
CO2 EMISSIONS POTENTIAL 1.7
LIGHTING COST CURRENT 57
LIGHTING COST POTENTIAL 63
HEATING COST CURRENT 136
HEATING COST POTENTIAL 134
HOT WATER COST CURRENT 916
HOT WATER COST POTENTIAL 199
TOTAL FLOOR AREA 52
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 86
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 86% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR heated corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.67
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION mechanical, extract only
ADDRESS Flat 25, Elizabeth Court, 47 Milmans Street
LOCAL AUTHORITY LABEL Kensington and Chelsea
CONSTITUENCY LABEL Chelsea and Fulham
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2021-09-10 15:29:46
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 12
UPRN 217057667
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000007
Address display
Nation ew