Energy Performance Certificate

12A JOHNS WALK, WHYTELEAFE, CR3 0BT

EPC Report

Energy rating

Current: 84 B | Potential: 93 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 84 B Current: 84 B 93 A Potential: 93 A

Environmental impact (CO₂)

Current: 85 | Potential: 93
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 85 Current: 85 93 Potential: 93
Field Value
LMK KEY 0360-3711-8020-2999-7355
ADDRESS1 12A JOHNS WALK
ADDRESS2 WHYTELEAFE
ADDRESS3
POSTCODE CR3 0BT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 84
POTENTIAL ENERGY EFFICIENCY 93
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2021-02-19
LOCAL AUTHORITY E07000215
CONSTITUENCY E14001215
COUNTY
LODGEMENT DATE 2021-02-19
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 85
ENVIRONMENT IMPACT POTENTIAL 93
ENERGY CONSUMPTION CURRENT 87
ENERGY CONSUMPTION POTENTIAL 33
CO2 EMISSIONS CURRENT 1.6
CO2 EMISS CURR PER FLOOR AREA 15
CO2 EMISSIONS POTENTIAL 0.6
LIGHTING COST CURRENT 79
LIGHTING COST POTENTIAL 79
HEATING COST CURRENT 288
HEATING COST POTENTIAL 288
HOT WATER COST CURRENT 66
HOT WATER COST POTENTIAL 66
TOTAL FLOOR AREA 105
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, plus solar
HOT WATER ENERGY EFF Very Good
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Average thermal transmittance 0.18 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.25 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.14 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and underfloor heating, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.53
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 12A JOHNS WALK, WHYTELEAFE
LOCAL AUTHORITY LABEL Tandridge
CONSTITUENCY LABEL East Surrey
POSTTOWN WHYTELEAFE
CONSTRUCTION AGE BAND 2012
LODGEMENT DATETIME 2021-02-19 14:03:36
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 16
LOW ENERGY FIXED LIGHT COUNT 16
UPRN 10007919729
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2021.csv
COUNTRY England
REGION E12000008
Address display
Nation ew