Energy Performance Certificate

5 Tawny Close, Edenfield, Ramsbottom, BL0 0GJ

EPC Report

Energy rating

Current: 88 B | Potential: 89 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 88 B Current: 88 B 89 B Potential: 89 B

Environmental impact (CO₂)

Current: 87 | Potential: 89
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 87 Current: 87 89 Potential: 89
Field Value
LMK KEY 0360-3054-4390-2124-2425
ADDRESS1 5 Tawny Close
ADDRESS2 Edenfield
ADDRESS3 Ramsbottom
POSTCODE BL0 0GJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 88
POTENTIAL ENERGY EFFICIENCY 89
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2024-01-24
LOCAL AUTHORITY E07000125
CONSTITUENCY E14001450
COUNTY
LODGEMENT DATE 2024-01-24
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 87
ENVIRONMENT IMPACT POTENTIAL 89
ENERGY CONSUMPTION CURRENT 88
ENERGY CONSUMPTION POTENTIAL 78
CO2 EMISSIONS CURRENT 2.3
CO2 EMISS CURR PER FLOOR AREA 16
CO2 EMISSIONS POTENTIAL 2.1
LIGHTING COST CURRENT 186
LIGHTING COST POTENTIAL 186
HEATING COST CURRENT 794
HEATING COST POTENTIAL 798
HOT WATER COST CURRENT 209
HOT WATER COST POTENTIAL 128
TOTAL FLOOR AREA 150
ENERGY TARIFF off-peak 7 hour
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.13 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.22 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.10 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and underfloor heating, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.39
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 5 Tawny Close, Edenfield, Ramsbottom
LOCAL AUTHORITY LABEL Rossendale
CONSTITUENCY LABEL Rossendale and Darwen
POSTTOWN BURY
CONSTRUCTION AGE BAND 2023
LODGEMENT DATETIME 2024-01-24 21:02:20
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 14
UPRN 10095978187
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2024.csv
COUNTRY England
REGION E12000002
Address display
Nation ew