Energy Performance Certificate

49 Fairfield, HX7 6JD

EPC Report

Energy rating

Current: 30 F | Potential: 51 E
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 30 F Current: 30 F 51 E Potential: 51 E

Environmental impact (CO₂)

Current: 40 | Potential: 56
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 40 Current: 40 56 Potential: 56
Field Value
LMK KEY 0360-2937-7410-2504-5151
ADDRESS1 49 Fairfield
ADDRESS2
ADDRESS3
POSTCODE HX7 6JD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING E
CURRENT ENERGY EFFICIENCY 30
POTENTIAL ENERGY EFFICIENCY 51
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2024-09-03
LOCAL AUTHORITY E08000033
CONSTITUENCY E14001147
COUNTY
LODGEMENT DATE 2024-09-10
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 40
ENVIRONMENT IMPACT POTENTIAL 56
ENERGY CONSUMPTION CURRENT 525
ENERGY CONSUMPTION POTENTIAL 385
CO2 EMISSIONS CURRENT 7.9
CO2 EMISS CURR PER FLOOR AREA 89
CO2 EMISSIONS POTENTIAL 5.8
LIGHTING COST CURRENT 112
LIGHTING COST POTENTIAL 112
HEATING COST CURRENT 3563
HEATING COST POTENTIAL 3222
HOT WATER COST CURRENT 692
HOT WATER COST POTENTIAL 324
TOTAL FLOOR AREA 89
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Less Than Typical
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Warm air, Electricaire
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.31
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 49 Fairfield
LOCAL AUTHORITY LABEL Calderdale
CONSTITUENCY LABEL Calder Valley
POSTTOWN HEBDEN BRIDGE
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2024-09-10 14:16:25
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 100051347926
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000003
Address display
Nation ew