Energy Performance Certificate

5 Selhurst Close, East Preston, BN16 2SR

EPC Report

Energy rating

Current: 68 D | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 68 D Current: 68 D 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 60 | Potential: 77
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 60 Current: 60 77 Potential: 77
Field Value
LMK KEY 0360-2684-5360-2604-1801
ADDRESS1 5 Selhurst Close
ADDRESS2 East Preston
ADDRESS3
POSTCODE BN16 2SR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 68
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2024-06-04
LOCAL AUTHORITY E07000224
CONSTITUENCY E14001599
COUNTY
LODGEMENT DATE 2024-06-06
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 60
ENVIRONMENT IMPACT POTENTIAL 77
ENERGY CONSUMPTION CURRENT 180
ENERGY CONSUMPTION POTENTIAL 94
CO2 EMISSIONS CURRENT 6.6
CO2 EMISS CURR PER FLOOR AREA 32
CO2 EMISSIONS POTENTIAL 3.5
LIGHTING COST CURRENT 178
LIGHTING COST POTENTIAL 178
HEATING COST CURRENT 2015
HEATING COST POTENTIAL 1421
HOT WATER COST CURRENT 256
HOT WATER COST POTENTIAL 154
TOTAL FLOOR AREA 208
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 4
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.36
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 5 Selhurst Close, East Preston
LOCAL AUTHORITY LABEL Arun
CONSTITUENCY LABEL Worthing West
POSTTOWN LITTLEHAMPTON
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2024-06-06 09:46:05
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 42
LOW ENERGY FIXED LIGHT COUNT 42
UPRN 100061725586
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000008
Address display
Nation ew