Energy Performance Certificate

Bower House, Station Road, Soberton, SO32 3QU

EPC Report

Energy rating

Current: 61 D | Potential: 71 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 61 D Current: 61 D 71 C Potential: 71 C

Environmental impact (CO₂)

Current: 52 | Potential: 63
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 52 Current: 52 63 Potential: 63
Field Value
LMK KEY 0360-2571-5440-2725-7965
ADDRESS1 Bower House
ADDRESS2 Station Road
ADDRESS3 Soberton
POSTCODE SO32 3QU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 61
POTENTIAL ENERGY EFFICIENCY 71
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2025-04-29
LOCAL AUTHORITY E07000094
CONSTITUENCY E14001587
COUNTY
LODGEMENT DATE 2025-04-30
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 52
ENVIRONMENT IMPACT POTENTIAL 63
ENERGY CONSUMPTION CURRENT 142
ENERGY CONSUMPTION POTENTIAL 101
CO2 EMISSIONS CURRENT 13
CO2 EMISS CURR PER FLOOR AREA 37
CO2 EMISSIONS POTENTIAL 9.5
LIGHTING COST CURRENT 231
LIGHTING COST POTENTIAL 231
HEATING COST CURRENT 2289
HEATING COST POTENTIAL 1882
HOT WATER COST CURRENT 224
HOT WATER COST POTENTIAL 184
TOTAL FLOOR AREA 339
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 95
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 9
NUMBER HEATED ROOMS 9
LOW ENERGY LIGHTING 84
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 84% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.6
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Bower House, Station Road, Soberton
LOCAL AUTHORITY LABEL Winchester
CONSTITUENCY LABEL Winchester
POSTTOWN SOUTHAMPTON
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2025-04-30 12:43:22
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 25
LOW ENERGY FIXED LIGHT COUNT 21
UPRN 100060593534
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000008
Address display
Nation ew