Energy Performance Certificate

140 Shard End Crescent, B34 7AD

EPC Report

Energy rating

Current: 77 C | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 77 C Current: 77 C 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 80 | Potential: 81
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 80 Current: 80 81 Potential: 81
Field Value
LMK KEY 0360-2346-4560-2125-3231
ADDRESS1 140 Shard End Crescent
ADDRESS2
ADDRESS3
POSTCODE B34 7AD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 77
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2025-06-26
LOCAL AUTHORITY E08000025
CONSTITUENCY E14001095
COUNTY
LODGEMENT DATE 2025-06-29
TRANSACTION TYPE Stock condition survey
ENVIRONMENT IMPACT CURRENT 80
ENVIRONMENT IMPACT POTENTIAL 81
ENERGY CONSUMPTION CURRENT 125
ENERGY CONSUMPTION POTENTIAL 111
CO2 EMISSIONS CURRENT 1.7
CO2 EMISS CURR PER FLOOR AREA 23
CO2 EMISSIONS POTENTIAL 1.6
LIGHTING COST CURRENT 68
LIGHTING COST POTENTIAL 68
HEATING COST CURRENT 461
HEATING COST POTENTIAL 461
HOT WATER COST CURRENT 127
HOT WATER COST POTENTIAL 127
TOTAL FLOOR AREA 77
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 80
NUMBER OPEN FIREPLACES
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Below average lighting efficiency
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 140 Shard End Crescent
LOCAL AUTHORITY LABEL Birmingham
CONSTITUENCY LABEL Birmingham Hodge Hill and Solihull North
POSTTOWN BIRMINGHAM
CONSTRUCTION AGE BAND England and Wales: 2012-2021
LODGEMENT DATETIME 2025-06-29 08:44:48
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 10094296245
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000005
Address display
Nation ew