Energy Performance Certificate

45 Tennyson Way, IP24 1LD

EPC Report

Energy rating

Current: 71 C | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 71 C Current: 71 C 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 70 | Potential: 73
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 70 Current: 70 73 Potential: 73
Field Value
LMK KEY 0360-2124-3670-2226-4001
ADDRESS1 45 Tennyson Way
ADDRESS2
ADDRESS3
POSTCODE IP24 1LD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 71
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2026-03-24
LOCAL AUTHORITY E07000143
CONSTITUENCY E14001497
COUNTY
LODGEMENT DATE 2026-03-24
TRANSACTION TYPE Non-marketed sale
ENVIRONMENT IMPACT CURRENT 70
ENVIRONMENT IMPACT POTENTIAL 73
ENERGY CONSUMPTION CURRENT 176
ENERGY CONSUMPTION POTENTIAL 150
CO2 EMISSIONS CURRENT 2.9
CO2 EMISS CURR PER FLOOR AREA 32
CO2 EMISSIONS POTENTIAL 2.6
LIGHTING COST CURRENT 59
LIGHTING COST POTENTIAL 59
HEATING COST CURRENT 841
HEATING COST POTENTIAL 776
HOT WATER COST CURRENT 194
HOT WATER COST POTENTIAL 195
TOTAL FLOOR AREA 90
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Good lighting efficiency
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.41
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 45 Tennyson Way
LOCAL AUTHORITY LABEL Breckland
CONSTITUENCY LABEL South West Norfolk
POSTTOWN THETFORD
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2026-03-24 14:10:23
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 16
LOW ENERGY FIXED LIGHT COUNT 16
UPRN 100090793048
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2026.csv
COUNTRY England
REGION E12000006
Address display
Nation ew