Energy Performance Certificate

67 High Street, Grantchester, CB3 9NF

EPC Report

Energy rating

Current: 47 E | Potential: 61 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 47 E Current: 47 E 61 D Potential: 61 D

Environmental impact (CO₂)

Current: 40 | Potential: 53
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 40 Current: 40 53 Potential: 53
Field Value
LMK KEY 0360-2094-6120-2102-2371
ADDRESS1 67 High Street
ADDRESS2 Grantchester
ADDRESS3
POSTCODE CB3 9NF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 47
POTENTIAL ENERGY EFFICIENCY 61
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2022-02-04
LOCAL AUTHORITY E07000012
CONSTITUENCY E14001481
COUNTY
LODGEMENT DATE 2022-02-21
TRANSACTION TYPE Assessment for Green Deal
ENVIRONMENT IMPACT CURRENT 40
ENVIRONMENT IMPACT POTENTIAL 53
ENERGY CONSUMPTION CURRENT 220
ENERGY CONSUMPTION POTENTIAL 160
CO2 EMISSIONS CURRENT 11
CO2 EMISS CURR PER FLOOR AREA 56
CO2 EMISSIONS POTENTIAL 7.8
LIGHTING COST CURRENT 229
LIGHTING COST POTENTIAL 115
HEATING COST CURRENT 1302
HEATING COST POTENTIAL 976
HOT WATER COST CURRENT 160
HOT WATER COST POTENTIAL 125
TOTAL FLOOR AREA 189
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 75
GLAZED TYPE secondary glazing
GLAZED AREA Normal
EXTENSION COUNT 4
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial secondary glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Timber frame, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.36
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 67 High Street, Grantchester
LOCAL AUTHORITY LABEL South Cambridgeshire
CONSTITUENCY LABEL South Cambridgeshire
POSTTOWN CAMBRIDGE
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2022-02-21 23:25:12
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 18
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100090143911
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000006
Address display
Nation ew