Energy Performance Certificate

2 Atlantic View, Fore Street, St. Dennis, PL26 8AD

EPC Report

Energy rating

Current: 29 F | Potential: 67 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 29 F Current: 29 F 67 D Potential: 67 D

Environmental impact (CO₂)

Current: 59 | Potential: 84
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 59 Current: 59 84 Potential: 84
Field Value
LMK KEY 0360-2069-9190-2072-3321
ADDRESS1 2 Atlantic View
ADDRESS2 Fore Street
ADDRESS3 St. Dennis
POSTCODE PL26 8AD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 29
POTENTIAL ENERGY EFFICIENCY 67
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2022-01-31
LOCAL AUTHORITY E06000052
CONSTITUENCY E14001508
COUNTY
LODGEMENT DATE 2022-01-31
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 59
ENVIRONMENT IMPACT POTENTIAL 84
ENERGY CONSUMPTION CURRENT 193
ENERGY CONSUMPTION POTENTIAL 56
CO2 EMISSIONS CURRENT 4.2
CO2 EMISS CURR PER FLOOR AREA 42
CO2 EMISSIONS POTENTIAL 1.5
LIGHTING COST CURRENT 80
LIGHTING COST POTENTIAL 80
HEATING COST CURRENT 1593
HEATING COST POTENTIAL 867
HOT WATER COST CURRENT 289
HOT WATER COST POTENTIAL 183
TOTAL FLOOR AREA 101
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Granite or whinstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, LPG
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL bottled LPG
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.34
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 2 Atlantic View, Fore Street, St. Dennis
LOCAL AUTHORITY LABEL Cornwall
CONSTITUENCY LABEL St Austell and Newquay
POSTTOWN ST. AUSTELL
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2022-01-31 20:10:18
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 11
UPRN 100041160466
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000009
Address display
Nation ew