Energy Performance Certificate

11, South View, Hart, TS27 3AZ

EPC Report

Energy rating

Current: 23 F | Potential: 69 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 23 F Current: 23 F 69 C Potential: 69 C

Environmental impact (CO₂)

Current: 11 | Potential: 42
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 11 Current: 11 42 Potential: 42
Field Value
LMK KEY 0359-2860-7426-9128-1795
ADDRESS1 11, South View
ADDRESS2 Hart
ADDRESS3
POSTCODE TS27 3AZ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 23
POTENTIAL ENERGY EFFICIENCY 69
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2018-02-20
LOCAL AUTHORITY E06000001
CONSTITUENCY E14001272
COUNTY
LODGEMENT DATE 2018-02-20
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 11
ENVIRONMENT IMPACT POTENTIAL 42
ENERGY CONSUMPTION CURRENT 913
ENERGY CONSUMPTION POTENTIAL 425
CO2 EMISSIONS CURRENT 14.0
CO2 EMISS CURR PER FLOOR AREA 154
CO2 EMISSIONS POTENTIAL 6.4
LIGHTING COST CURRENT 67
LIGHTING COST POTENTIAL 67
HEATING COST CURRENT 2111
HEATING COST POTENTIAL 1040
HOT WATER COST CURRENT 311
HOT WATER COST POTENTIAL 102
TOTAL FLOOR AREA 89
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.45
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 11, South View, Hart
LOCAL AUTHORITY LABEL Hartlepool
CONSTITUENCY LABEL Hartlepool
POSTTOWN HARTLEPOOL
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2018-02-20 20:22:13
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 12
UPRN 100110028444
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000001
Address display
Nation ew