Energy Performance Certificate

Waylands, Townsend, Curry Rivel, TA10 0HP

EPC Report

Energy rating

Current: 22 F | Potential: 75 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 22 F Current: 22 F 75 C Potential: 75 C

Environmental impact (CO₂)

Current: 4 | Potential: 45
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 4 Current: 4 45 Potential: 45
Field Value
LMK KEY 0358-7046-7238-6451-9940
ADDRESS1 Waylands
ADDRESS2 Townsend
ADDRESS3 Curry Rivel
POSTCODE TA10 0HP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 22
POTENTIAL ENERGY EFFICIENCY 75
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2019-08-05
LOCAL AUTHORITY E06000066
CONSTITUENCY E14001247
COUNTY
LODGEMENT DATE 2019-08-06
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 4
ENVIRONMENT IMPACT POTENTIAL 45
ENERGY CONSUMPTION CURRENT 836
ENERGY CONSUMPTION POTENTIAL 294
CO2 EMISSIONS CURRENT 15.0
CO2 EMISS CURR PER FLOOR AREA 145
CO2 EMISSIONS POTENTIAL 5.3
LIGHTING COST CURRENT 78
LIGHTING COST POTENTIAL 79
HEATING COST CURRENT 2107
HEATING COST POTENTIAL 857
HOT WATER COST CURRENT 447
HOT WATER COST POTENTIAL 114
TOTAL FLOOR AREA 104
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 50
GLAZED TYPE secondary glazing
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial secondary glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Sandstone or limestone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.72
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Waylands, Townsend, Curry Rivel
LOCAL AUTHORITY LABEL Somerset
CONSTITUENCY LABEL Glastonbury and Somerton
POSTTOWN LANGPORT
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2019-08-06 14:54:20
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 17
LOW ENERGY FIXED LIGHT COUNT 17
UPRN 30095041
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000009
Address display
Nation ew