Energy Performance Certificate

19, Wallace Court, PO30 2DF

EPC Report

Energy rating

Current: 61 D | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 61 D Current: 61 D 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 60 | Potential: 82
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 60 Current: 60 82 Potential: 82
Field Value
LMK KEY 0358-2801-7675-9503-0091
ADDRESS1 19, Wallace Court
ADDRESS2
ADDRESS3
POSTCODE PO30 2DF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 61
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE Bungalow
BUILT FORM Semi-Detached
INSPECTION DATE 2017-03-09
LOCAL AUTHORITY E06000046
CONSTITUENCY E14001304
COUNTY
LODGEMENT DATE 2017-03-09
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 60
ENVIRONMENT IMPACT POTENTIAL 82
ENERGY CONSUMPTION CURRENT 294
ENERGY CONSUMPTION POTENTIAL 92
CO2 EMISSIONS CURRENT 2.5
CO2 EMISS CURR PER FLOOR AREA 52
CO2 EMISSIONS POTENTIAL 0.8
LIGHTING COST CURRENT 40
LIGHTING COST POTENTIAL 40
HEATING COST CURRENT 506
HEATING COST POTENTIAL 420
HOT WATER COST CURRENT 82
HOT WATER COST POTENTIAL 51
TOTAL FLOOR AREA 48
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 83
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Timber frame, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 83% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 19, Wallace Court
LOCAL AUTHORITY LABEL Isle of Wight
CONSTITUENCY LABEL Isle of Wight West
POSTTOWN NEWPORT
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2017-03-09 09:12:58
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 10003317514
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000008
Address display
Nation ew