Energy Performance Certificate

22, Deepmore Road, CV22 7PZ

EPC Report

Energy rating

Current: 56 D | Potential: 75 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 56 D Current: 56 D 75 C Potential: 75 C

Environmental impact (CO₂)

Current: 52 | Potential: 76
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 52 Current: 52 76 Potential: 76
Field Value
LMK KEY 0358-1047-6247-5770-7264
ADDRESS1 22, Deepmore Road
ADDRESS2
ADDRESS3
POSTCODE CV22 7PZ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 56
POTENTIAL ENERGY EFFICIENCY 75
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2020-03-05
LOCAL AUTHORITY E07000220
CONSTITUENCY E14001453
COUNTY
LODGEMENT DATE 2020-03-05
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 52
ENVIRONMENT IMPACT POTENTIAL 76
ENERGY CONSUMPTION CURRENT 400
ENERGY CONSUMPTION POTENTIAL 196
CO2 EMISSIONS CURRENT 3.2
CO2 EMISS CURR PER FLOOR AREA 70
CO2 EMISSIONS POTENTIAL 1.6
LIGHTING COST CURRENT 39
LIGHTING COST POTENTIAL 39
HEATING COST CURRENT 524
HEATING COST POTENTIAL 274
HOT WATER COST CURRENT 176
HOT WATER COST POTENTIAL 96
TOTAL FLOOR AREA 46
ENERGY TARIFF dual (24 hour)
MAINS GAS FLAG Y
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Room heaters, mains gas
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 7.3
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 22, Deepmore Road
LOCAL AUTHORITY LABEL Rugby
CONSTITUENCY LABEL Rugby
POSTTOWN RUGBY
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2020-03-05 17:35:36
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 100070182878
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000005
Address display
Nation ew