Energy Performance Certificate

56, Blue Anchor Chalets, TA24 6LE

EPC Report

Energy rating

Current: 36 F | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 36 F Current: 36 F 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 43 | Potential: 66
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 43 Current: 43 66 Potential: 66
Field Value
LMK KEY 0358-0086-7201-2974-5980
ADDRESS1 56, Blue Anchor Chalets
ADDRESS2
ADDRESS3
POSTCODE TA24 6LE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 36
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2014-09-05
LOCAL AUTHORITY E06000066
CONSTITUENCY E14001548
COUNTY
LODGEMENT DATE 2014-09-07
TRANSACTION TYPE FiT application
ENVIRONMENT IMPACT CURRENT 43
ENVIRONMENT IMPACT POTENTIAL 66
ENERGY CONSUMPTION CURRENT 429
ENERGY CONSUMPTION POTENTIAL 226
CO2 EMISSIONS CURRENT 4.1
CO2 EMISS CURR PER FLOOR AREA 76
CO2 EMISSIONS POTENTIAL 2.1
LIGHTING COST CURRENT 54
LIGHTING COST POTENTIAL 59
HEATING COST CURRENT 791
HEATING COST POTENTIAL 409
HOT WATER COST CURRENT 304
HOT WATER COST POTENTIAL 76
TOTAL FLOOR AREA 54
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS None
MULTI GLAZE PROPORTION 90
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING 50
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, with internal insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated at rafters
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 50% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL To be used only when there is no heating/hot-water system
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.14
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 56, Blue Anchor Chalets
LOCAL AUTHORITY LABEL Somerset
CONSTITUENCY LABEL Tiverton and Minehead
POSTTOWN MINEHEAD
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2014-09-07 12:28:43
TENURE Rented (private)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 10003763171
UPRN SOURCE Address Matched
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000009
Address display