Energy Performance Certificate

19a, High Street, CT6 5LJ

EPC Report

Energy rating

Current: 36 F | Potential: 70 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 36 F Current: 36 F 70 C Potential: 70 C

Environmental impact (CO₂)

Current: 22 | Potential: 50
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 22 Current: 22 50 Potential: 50
Field Value
LMK KEY 0358-0071-6229-9138-9964
ADDRESS1 19a, High Street
ADDRESS2
ADDRESS3
POSTCODE CT6 5LJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 36
POTENTIAL ENERGY EFFICIENCY 70
PROPERTY TYPE Maisonette
BUILT FORM Mid-Terrace
INSPECTION DATE 2018-01-05
LOCAL AUTHORITY E07000106
CONSTITUENCY E14001282
COUNTY
LODGEMENT DATE 2018-01-05
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 22
ENVIRONMENT IMPACT POTENTIAL 50
ENERGY CONSUMPTION CURRENT 580
ENERGY CONSUMPTION POTENTIAL 297
CO2 EMISSIONS CURRENT 8.8
CO2 EMISS CURR PER FLOOR AREA 98
CO2 EMISSIONS POTENTIAL 4.5
LIGHTING COST CURRENT 98
LIGHTING COST POTENTIAL 71
HEATING COST CURRENT 1276
HEATING COST POTENTIAL 511
HOT WATER COST CURRENT 291
HOT WATER COST POTENTIAL 164
TOTAL FLOOR AREA 90
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Automatic charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 63
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Roof room(s), ceiling insulated
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Automatic charge control
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 63% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.85
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 19a, High Street
LOCAL AUTHORITY LABEL Canterbury
CONSTITUENCY LABEL Herne Bay and Sandwich
POSTTOWN HERNE BAY
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2018-01-05 16:26:12
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100060834058
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000008
Address display
Nation ew