Energy Performance Certificate

38 Girton Court, Wratten Close, SG5 2BL

EPC Report

Energy rating

Current: 67 D | Potential: 67 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 67 D Current: 67 D 67 D Potential: 67 D

Environmental impact (CO₂)

Current: 64 | Potential: 64
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 Current: 64 64 Potential: 64
Field Value
LMK KEY 0357-3007-0204-9014-6204
ADDRESS1 38 Girton Court
ADDRESS2 Wratten Close
ADDRESS3
POSTCODE SG5 2BL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 67
POTENTIAL ENERGY EFFICIENCY 67
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2024-04-05
LOCAL AUTHORITY E07000099
CONSTITUENCY E14001289
COUNTY
LODGEMENT DATE 2024-04-05
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 64
ENVIRONMENT IMPACT POTENTIAL 64
ENERGY CONSUMPTION CURRENT 309
ENERGY CONSUMPTION POTENTIAL 309
CO2 EMISSIONS CURRENT 2.2
CO2 EMISS CURR PER FLOOR AREA 55
CO2 EMISSIONS POTENTIAL 2.2
LIGHTING COST CURRENT 60
LIGHTING COST POTENTIAL 60
HEATING COST CURRENT 622
HEATING COST POTENTIAL 622
HOT WATER COST CURRENT 190
HOT WATER COST POTENTIAL 190
TOTAL FLOOR AREA 40
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Flat rate charging, TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Community scheme
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION System built, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Community scheme
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Flat rate charging, TRVs
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR heated corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.39
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 38 Girton Court, Wratten Close
LOCAL AUTHORITY LABEL North Hertfordshire
CONSTITUENCY LABEL Hitchin
POSTTOWN Hitchin
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2024-04-05 15:41:56
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100081128327
UPRN SOURCE Address Matched
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000006
Address display
Nation ew