Energy Performance Certificate

Flat 5, 6 Crayford Way, Crayford, DA1 4LQ

EPC Report

Energy rating

Current: 47 E | Potential: 51 E
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 47 E Current: 47 E 51 E Potential: 51 E

Environmental impact (CO₂)

Current: 53 | Potential: 56
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 53 Current: 53 56 Potential: 56
Field Value
LMK KEY 0357-2800-7527-9123-7191
ADDRESS1 Flat 5
ADDRESS2 6 Crayford Way
ADDRESS3 Crayford
POSTCODE DA1 4LQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING E
CURRENT ENERGY EFFICIENCY 47
POTENTIAL ENERGY EFFICIENCY 51
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2017-02-20
LOCAL AUTHORITY E09000004
CONSTITUENCY E14001089
COUNTY
LODGEMENT DATE 2017-02-20
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 53
ENVIRONMENT IMPACT POTENTIAL 56
ENERGY CONSUMPTION CURRENT 778
ENERGY CONSUMPTION POTENTIAL 721
CO2 EMISSIONS CURRENT 2.0
CO2 EMISS CURR PER FLOOR AREA 132
CO2 EMISSIONS POTENTIAL 1.8
LIGHTING COST CURRENT 32
LIGHTING COST POTENTIAL 16
HEATING COST CURRENT 403
HEATING COST POTENTIAL 376
HOT WATER COST CURRENT 149
HOT WATER COST POTENTIAL 149
TOTAL FLOOR AREA 15
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 1
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 3.8
FLOOR HEIGHT 2.45
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 5, 6 Crayford Way, Crayford
LOCAL AUTHORITY LABEL Bexley
CONSTITUENCY LABEL Bexleyheath and Crayford
POSTTOWN DARTFORD
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2017-02-20 16:12:24
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 4
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 10096984458
UPRN SOURCE Address Matched
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000007
Address display
Nation ew