Energy Performance Certificate

Jaspers, Mill Lane, PL32 9UF

EPC Report

Energy rating

Current: 32 F | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 32 F Current: 32 F 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 18 | Potential: 60
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 18 Current: 18 60 Potential: 60
Field Value
LMK KEY 0356-2820-7055-9173-9195
ADDRESS1 Jaspers
ADDRESS2 Mill Lane
ADDRESS3
POSTCODE PL32 9UF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 32
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2017-05-30
LOCAL AUTHORITY E06000052
CONSTITUENCY E14001385
COUNTY
LODGEMENT DATE 2017-05-31
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 18
ENVIRONMENT IMPACT POTENTIAL 60
ENERGY CONSUMPTION CURRENT 717
ENERGY CONSUMPTION POTENTIAL 257
CO2 EMISSIONS CURRENT 11
CO2 EMISS CURR PER FLOOR AREA 121
CO2 EMISSIONS POTENTIAL 3.9
LIGHTING COST CURRENT 65
LIGHTING COST POTENTIAL 65
HEATING COST CURRENT 1637
HEATING COST POTENTIAL 653
HOT WATER COST CURRENT 273
HOT WATER COST POTENTIAL 99
TOTAL FLOOR AREA 90
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 91
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 50 mm loft insulation
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.27
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Jaspers, Mill Lane
LOCAL AUTHORITY LABEL Cornwall
CONSTITUENCY LABEL North Cornwall
POSTTOWN CAMELFORD
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2017-05-31 16:40:48
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 100041163459
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000009
Address display
Nation ew